Teknisk data
Läge | effekt max | Utgångs min. | Flödeshastighet max. | Flödeshastighet min. | strömförsörjning | Motor | Förpackningsstorlek | vikt | |||
KW | Kcal / h x 10 | 4 | KW | Kcal / h × 104 | Kg / h | Kg / h | V | KW | L × P × H mm | kg | |
M-3LF | 42,7 | 3 | 8 | 0,65 | 3 | 0,65 | 230V / 50Hz | 0,09 | 490 × 300 × 320 | 10 | |
M-6LF | 74,3 | 6 | 31,9 | 2,75 | 6 | 3 | 0,11 | 490 × 300 × 320 | 12 | ||
M-10LF | 118 | 10 | 60 | 5 | 10 | 5 | 0,11 | 490 × 300 × 320 | 12 | ||
M-14LF | 172 | 14 | 89 | 7,5 | 14 | 7,5 | 0,15 | 470 × 455 × 340 | 15 | ||
M-14LFW * | 172 | 14 | 89 | 7,5 | 14 | 7,5 | 0,15 | 480 × 455 × 340 | 17,5 | ||
M-18LF | 213 | 18 | 90 | 8 | 18 | 8 | 0,37 | 650 × 520 × 385 | 23 | ||
M-26LF | 308 | 26 | 154 | 13 | 26 | 13 | 0,37 | 650 × 520 × 385 | 23 | ||
M-35LF | 391 | 34 | 178 | 15 | 34 | 15 | 0,37 | 805 × 525 × 405 | 26 | ||
M-40LF | 474 | 40 | 237 | 20 | 40 | 20 | 380V / 50Hz | 0,37 | 1100 × 600 × 450 | 54 |
* Med vattentäta locket
Curve Diagram
Generella dimensioner
Modell | en |
B |
C | D | E |
F |
L mmThe storlek mellan installationshålen | Nφmm | M | NEJ . | |
Widthmm | Heightmm | Lengthmm | Längd blast tubemm |
φmmHead diameter | φmmCylinder diameter |
min | max | ||||
M-K10KL | 300 |
230 |
400 | 105 | 90 |
90 |
130 | 155 | 95 | M8 |
1 |
M-8SL | 330 |
220 |
220 | 120 | 89 |
89 |
130 | 155 | 95 | M8 |
1 |
M-12SL | 330 |
220 |
220 | 140 | 89 |
89 |
130 | 155 | 95 | M8 |
1 |
M-3L | 250 |
217,5 |
330 | 90 | 80 |
80 |
135 | 160 | 90 | M8 |
1 |
M-6L | 245 |
270 |
455 | 150 | 90 |
90 |
130 | 155 | 100 | M8 |
1 |
M-10L | 245 |
270 |
480 | 130 | 95 |
95 |
130 | 155 | 100 | M8 |
1 |
M-14L | 360 |
275 |
415 | 110 | 95 |
95 |
130 | 155 | 105 | M8 |
2 |
M-14LW | 380 |
275 |
415 | 110 | 95 |
95 |
130 | 155 | 130 | M8 |
2 |
M-18L | 360 |
355 |
650 | 117 | 118 |
114 |
170 | 206 | 130 | M10 |
2 |
M-26L | 450 |
355 |
650 | 139 | 135 |
114 |
170 | 206 | 150 | M10 |
2 |
M-34L | 480 |
380 |
740 | 380 | 150 |
135 |
200 | 244 | 165 | M12 |
2 |
M-35L | 450 |
372,5 |
780 | 350 | 150 |
135 |
200 | 244 | 165 | M12 |
2 |
M-40L | 525 |
430 |
985 | 305 | 170 |
135 |
200 | 244 | 180 | M12 |
2 |
M-55L | 600 |
500 |
1170 | 400 | 170 |
135 |
200 | 244 | 180 | M12 |
2 |
* M-75L | 630 |
510 |
1200 | 400 | 205 |
160 |
233 | 180 | M12 |
3 |
|
M-100L | 640 |
525 |
1295 | 400 | 230 |
195 |
276 | 240 | M16 |
3 |
|
M-120L | 685 |
610 |
1400 | 400 | 230 |
195 |
276 | 240 | M16 |
3 |
|
M-180L | 785 |
650 |
1645 | 535 | 260 |
220 |
339 | 270 | M16 |
3 |
|
M-250L | 915 |
780 |
1665 | 590 | 260 |
220 |
339 | 270 | M16 |
3 |
|
M-300L | 915 |
840 |
1860 | 605 | 360 |
275 |
480 | 510 | 380 | M20 |
5 |
M-350L | 1050 |
920 |
1960 | 560 | 360 |
275 |
480 | 510 | 380 | M20 |
5 |
”W” Med vattentäta locket
”N” betyder storleken på hålet på kammaren.
När ”E” är större än ”N”, förutom utan furance dörr på denna panna, vänligen öppna hålet ”N” större än ”E” och behöver en extravagant fläns för att installera brännaren. Kontakta sälja kontoret om behöver några fler detaljer.