The M series burners, the Mechanical &Electrical Integration burners which extensive use the steam boilers, heating water boilers, heat conducting oil stove, direct-fired generator, lithium bromide air-conditioning plant and other industrial heating and parch stove equipments, are designed by advanced combustion technology in the world and consult the EN267 Standard and the national interr- elated standard.


  • Min.Order Quantity: 100 Piece/Pieces
  • Supply Ability: 10000 Piece/Pieces per Month
  • Port: Shanghai
  • Payment Terms: L/C,D/A,D/P,T/T
  • Product Detail

    Product Tags

    05

    Technical data

    Model Output max. Output min. Flow rate max. Flow rate min. Power supply Motor Packing Size Weight
    KW Nm3/h KW Nm3/h Kg/h

    Kg/h

    V KW L×P×H mm

    Kg

    M-11GL 103 10.3 59 5.8 8.7

    4.9

    230V/50Hz 0.15+0.11 600×480×340

    25

    M-20GL 230 23 80 8 19.4

    6.7

    0.37+0.11 850×550×400

    42

    M-35GL 340 35 130 13 30

    11

    0.37+0.15 900×550×400

    45

    curve diagram

    74104

    Overall dimensions

    253

     

    5755

    42

     

     

    Model A B C D E F L mmThe size between the
    installation holes
    Nφmm M NO .
    Widthmm Heightmm Lengthmm Length of
    blast tubemm
    φmmHead
    diameter
    φmmCylinder
    diameter
    min max
    M-11GL 475.4 292.5 595 40-160 95 95 130 155 115 M8 1
    M-20GL 537 345 807 120-280 135 114 170 206 145 M10 1
    M-35GL 537 354 858 140-300 150 135 200 244 160 M12 1
    M-35GLR 537 354 858 140-300 150 135 200 244 160 M12 1
    M-40GLR 596.5 435 1131 140-322 160 233 170 M12 2
    M-100GLR 717 530 1285 175-380 195 276 205 M16 2
    M-120GLR 809 645.5 1501 195-460 218 339 240 M16 2
    M-180GLR 810 675 1700 330-640 290 244 400 300 M18 3
    M-250GLR 1033 860 1805 320-500 356 275 480 510 370 M20 4
    M-350GLR 1100 860 1805 320-550 356 275 480 510 370 M20 4
    M-450GL S /M 962 740 1540 335 290 320 400 330 M16 2
    M-550GL S /M 965 780 1660 399 350 380 480 390 M16 2
    M-650GL S /M 1125 1075 1645 430 480 470 550 500 M16 3
       M-1000GL S /M 1230 1094 1670 430 480 470 550 500 M16 3

    Protection probe.Manual adjusting air gate to control for one stage
    UV photocell,servo motor to control for two stage and modulating.
    Able to supply the low calorific valve fuel,low gas pressure & light oil (Heavy oil)dual fuel burners and oil & gas mixing combustion burner.
    “N”means the size of the hole on the chamber.