Technical data
Model | Output max. | Output min. | Gas pressure gas | Power supply | Motor | Packing Size | weight | ||
KW | Kcal/h×104 | KW | Kcal/h×104 |
mbar |
V | KW | L×P×H mm | Kg | |
M-17G S/M | 168 | 14.5 | 50 | 5 |
20-200 |
230V/50Hz | 0.15 | 570×465×340 | 18 |
M-35G S/M | 340 | 30 | 60 | 6 |
20-200 |
0.37 | 990×550×450 | 50 | |
M-40G S/M | 425 | 36.5 | 185 | 16 |
20-300 |
380V/50Hz | 0.37 | 900×650×450 | 80 |
M-60G S/M | 738 | 63.5 | 248 | 21.4 |
30-300 |
1.1 |
1000×760×550 |
118 | |
M-100G S/M | 995 | 85 | 280 | 24 |
30-300 |
1.1 |
1000×760×550 |
120 | |
M-120G S/M | 1200 | 105 | 350 | 30 |
30-300 |
1.5 |
1050×850×580 |
130 | |
M-150G S/M | 1428 | 123 | 414 | 35.7 |
30-300 |
2.2 | 1150×850×650 | 154 | |
M-200G S/M | 2000 | 172.5 | 490 | 42.2 |
40-300 |
3.0 |
1400×1080×800 |
320 | |
M-250G S/M | 2500 | 215.5 | 590 | 50.8 |
40-300 |
7.5 |
1400×1080×800 |
330 | |
M-350G S/M | 3500 | 300 | 924 | 79.7 |
40-300 |
7.5 |
1500×1080×800 |
340 | |
M-400G S/M | 3800 | 327 | 924 | 79.7 |
40-300 |
9.0 |
1500×1080×800 |
360 | |
M-450G S/M | 4000 | 345 | 550 | 48 |
40-500 |
9 |
1700×1100×850 |
228 | |
M-550G S/M | 5400 | 465 | 600 | 52 |
50-500 |
13.5 |
1800×1250×850 |
230 | |
M-650G S/M | 7400 | 638 | 800 | 69 |
100-500 |
18.5 |
2200×1300×1300 |
330 | |
M-1000G S/M | 10500 | 905 | 1000 | 86 |
100-500 |
22 |
2200×1300×1300 |
335 |
Sliding:the servo motor moves the cam to control the butterfly valve.
Modulating:Install PID adjusting controller with digital display.
Fuel:/Natural Gas (L.C.V 8570kcal/Nm3)
LPG (L.C.V 22260kcal/Nm3)
Sliding/Modulating curve diagram
Overall dimensions
Model | A | B | C | D | E | F | L mm The size between the installation holes | Nφmm | M | NO . | |
Width mm | Height mm | Length mm | Length of blast tube mm | φmm Head diameter | φmm Cylinderdiameter | ||||||
M-450GS /M | 962 | 740 | 1540 | 335 | 290 | 320 |
400 |
330 | M16 | 1 | |
M-550GS /M | 965 | 780 | 1660 | 399 | 350 | 380 |
480 |
390 | M16 | 1 | |
M-650GS /M | 1125 | 1075 | 1645 | 430 | 480 | 470 |
550 |
500 | M16 | 2 | |
M-1000GS /M | 1230 | 1094 | 1670 | 430 | 480 | 470 |
550 |
500 | M16 | 2 |
“N”means the size of the hole on the chamber.
Model | A | B | C | D | E |
F |
L mmThe size between the installation holes | Nφmm | M | NO . | ||
Widthmm | Heightmm | Lengthmm | Length of blast tubemm |
φmmHead diameter |
φmmCylinder diameter |
min | 最大max | |||||
M-3G | 245 | 270 | 410 | 50-105 | 90 |
90 |
130 | 155 | 95 | M8 |
1 |
|
M-6G | 245 | 271.5 | 410 | 50-105 | 90 |
90 |
130 | 155 | 100 | M8 |
1 |
|
M-11G | M-11TG | 245 | 271.5 | 475 | 90-150 | 108 |
90 |
130 | 155 | 120 | M8 |
1 |
M-17G | M-17TG | 350 | 350 | 650 | 80-200 | 108 |
95 |
130 | 155 | 120 | M8 |
2 |
M-20G | 475 | 365 | 740 | 120-280 | 135 |
114 |
170 | 206 | 140 | M10 |
3 |
|
M-30G | M-30TG | 475 | 365 | 835 | 170-300 | 135 |
135 |
200 | 244 | 145 | M12 |
3 |
M-35G | M-35TG | 475 | 365 | 925 | 130-350 | 155 |
135 |
200 | 244 | 165 | M12 |
3 |
M-40G | M-40TG | 470 | 397 | 1100 | 150-330 | 155 |
135 |
200 | 244 | 165 | M12 |
3 |
M-50G | 475 | 397 | 1150 | 150-350 | 155 |
135 |
200 | 244 | 165 | M12 |
3 |
|
*M-60G | *M-60TG | 560 | 485 | 1270 | 170-400 | 205 |
160 |
233 | 190 | M12 |
4 |
|
*M-100G | 560 | 485 | 1330 | 240-460 | 230 |
160 |
233 | 190 | M12 |
4 |
||
*M-100TG | 560 | 485 | 1330 | 220-440 | 270 | 195 | 276 | 220 | M16 |
4 |
||
*M-120G | 590 | 500 | 1400 | |||||||||
*M-150G | 655 | 587 | 1500 | 220-440 | 270 |
195 |
276 | 220 | M16 |
4 |
||
*M-150TG | 655 | 587 | 1500 | 300-600 | 320 | 220 | 339 | 240 | M16 |
4 |
||
*M-200G | 830 | 730 | 1850 | |||||||||
*M-250G | 875 | 730 | 1850 | 300-600 | 320 |
220 |
339 | 240 | M16 |
4 |
||
M-250TG | 875 | 730 | 1850 | 275-450 | 356 | 275 | 480 | 510 | 390 | M20 |
5 |
|
M-300G | 875 | 757 | 1850 | |||||||||
M-350G | 880 | 757 | 1850 | 275-450 | 356 |
275 |
480 | 510 | 390 | M20 |
5 |
|
M-400G | 880 | 760 | 1850 | 275-450 | 356 |
275 |
480 | 510 | 390 | M20 |
5 |
“N”means the size of the hole on the chamber.
When“E”is greater than“N”,besides without furance door on this boiler,please open the hole“N”greater than “E”and need one extravagant flange to install the burner. Contact sell office if need any more details.